LOGIN

SEARCH

Wyślij broszurę ask for product złóż zamówienie
DOUBLE-DIODE MODULE – MOC..P
POWER BLOCK – photo1 MOC MOK MOA


DOUBLE-DIODE POWER BLOCK WITH RY HEATSINK

Characteristics:
• double-diode power module with double-sided cooling in heatsink – RY;
• natural cooling.

Applications:
• rectifiers,
• power supplies.

Selection of power blocks:
Depending on the load of power block there are used different semiconductors. Size of the applied semiconductor is specified in Table 1.
Options:
• standard version (photo 1);
• with bus bars;
• with black anodized heatsink;
• thermal protection;
• RC system;
• fuse;
• forced cooling.

Working conditions:
Double-element power blocks are assigned to work in power electronic inverter systems:
• temperature of ambient air: -100C – +400C;
• atmospheric pressure: 860hPa – 1060hPa;
• relative humidity not higher than 80% for temperature 400C;
• cooling air without aggressive chemical agents nor conductive dut.

Table 1. Technical parameters of power blocks

Type of module Medium current
of
semiconductor IT(AV)
[A]
Reverse voltage
and blocking
voltage of
semiconductor
UDRM, URRM
[V]
Overload current
ITSM
[A]
Dimensions of applied
semiconductor
[mm]
Mass
of block
[kg]
MOC7P 450…650 400…2400 7000…10000 13,80
MOC8P 630…1000 400…8500 10000…24000 14,20
MOC9P 1000…2000 400…7500 20000…42000 16,40
MOC11P 1000…3200 400…6000 27000…65000 18,30

Scheme of power blocks — type MOC..P



Directions of purchasing: MOC7P -1000 -20 Diode volatge URRM x 100

Diode size. Table 1.aa

   Diode current IF(AV)

Our suppliers: